APC Back-UPS – 120V, 350VA, 210-Watt, 6-Outlet

Part Number: BK350

 

  • Circuit breaker forces the UPS to disconnect itself from utility power if it detects an overload condition.
  • Two of the receptacles accept transformer blocks.
  • Includes straps to manage power cords plugged into the UPS.
  • Uses USB connection to communicate with UPS during management software installation. USB cable and software are included.
  • Site-wiring fault indicator identifies potentially dangerous wiring problems.
  • Gives you the runtime needed for you to work through power disturbances, save data, and shut down safely.
  • Three outlets provide battery backup and surge protection. Use to connect a data-sensitive computer, monitor, and external disk or CD-ROM drive.
  • Also has three surge protection-only outlets for plugging in and protecting equipment not requiring continuous operation.
  • RJ-11 ports offer lightning surge protection for any device connected to the telephone line, such as a modem or phone. Compatible with DSL and HPNA standards, as well as all modem data rates.
  • Optimized for use with Windows® 98/Me/2000/XP systems to support data reporting, data saving, and unattended shutdown of computers connected to the UPS.
  • Offers 210-watt/350-VA output power capacity.

 

General
Diagnostics LEDs: On Line; On Battery; Replace Battery; Overload; Audible alarms: On battery, distinctive low battery alarm, overload continuous tone alarm
Interface (1) 10-pin RJ-45 (interfaces with a computer’s USB port via the included RJ-45-to-USB cable)
Outlets (3) surge plus battery backup, (3) surge only
Output Power 210 W/350 VA
Power Primary voltage: 120 VAC, 50/60 Hz
Protected Telephone/Fax/Modem Ports (1) RJ-11 in, (1) RJ-11 out
Runtimes Maximum: 47 minutes at 50 W/80V; Full load: 5 minutes (210 W); Half load: 18 minutes (105 W)
Surge Energy Rating 1020 joules